Show simple item record

dc.contributor.authorFoo, BC
dc.contributor.authorBuschmann, BI
dc.contributor.authorCufari, M
dc.contributor.authorDannhoff, SG
dc.contributor.authorDeVault, A
dc.contributor.authorEvans, TE
dc.contributor.authorJohnson, TM
dc.contributor.authorKunimune, JH
dc.contributor.authorLawrence, Y
dc.contributor.authorPearcy, JA
dc.contributor.authorReichelt, BL
dc.contributor.authorRussell, L
dc.contributor.authorVanderloo, N
dc.contributor.authorVargas, J
dc.contributor.authorWink, CW
dc.contributor.authorJohnson, M Gatu
dc.contributor.authorSéguin, FH
dc.contributor.authorPetrasso, RD
dc.contributor.authorFrenje, JA
dc.date.accessioned2026-04-07T14:36:44Z
dc.date.available2026-04-07T14:36:44Z
dc.date.issued2024-10-31
dc.identifier.urihttps://hdl.handle.net/1721.1/165346
dc.description.abstractCR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.en_US
dc.language.isoen
dc.publisherAIP Publishingen_US
dc.relation.isversionofhttps://doi.org/10.1063/5.0219510en_US
dc.rightsCreative Commons Attributionen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en_US
dc.sourceAIP Publishingen_US
dc.titleErrors in the field reconstruction using CR-39 proton radiographs with high fluence variationen_US
dc.typeArticleen_US
dc.identifier.citationB. C. Foo, B. I. Buschmann, M. Cufari, S. G. Dannhoff, A. DeVault, T. E. Evans, T. M. Johnson, J. H. Kunimune, Y. Lawrence, J. A. Pearcy, B. L. Reichelt, L. Russell, N. Vanderloo, J. Vargas, C. W. Wink, M. Gatu Johnson, F. H. Séguin, R. D. Petrasso, J. A. Frenje; Errors in the field reconstruction using CR-39 proton radiographs with high fluence variation. Rev. Sci. Instrum. 1 October 2024; 95 (10): 103527.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Plasma Science and Fusion Centeren_US
dc.relation.journalReview of Scientific Instrumentsen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2026-04-07T14:31:57Z
dspace.orderedauthorsFoo, BC; Buschmann, BI; Cufari, M; Dannhoff, SG; DeVault, A; Evans, TE; Johnson, TM; Kunimune, JH; Lawrence, Y; Pearcy, JA; Reichelt, BL; Russell, L; Vanderloo, N; Vargas, J; Wink, CW; Johnson, MG; Séguin, FH; Petrasso, RD; Frenje, JAen_US
dspace.date.submission2026-04-07T14:31:59Z
mit.journal.volume95en_US
mit.journal.issue10en_US
mit.licensePUBLISHER_CC
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record