Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Author(s)
Buschmann, BI; Cufari, M; Vanderloo, N; Vargas, J; Foo, BC; DeVault, A; Dannhoff, SG; Evans, TE; Johnson, TM; Kunimune, JH; Lawrence, Y; Pearcy, JA; Reichelt, BL; Wink, CW; Russell, L; Gatu Johnson, M; Petrasso, RD; Frenje, JA; ... Show more Show less
Thumbnail
DownloadPublished version (4.984Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution https://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.
Date issued
2024-09-20
URI
https://hdl.handle.net/1721.1/165099
Department
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Journal
Review of Scientific Instruments
Publisher
AIP Publishing
Citation
B. I. Buschmann, M. Cufari, N. Vanderloo, J. Vargas, B. C. Foo, A. DeVault, S. G. Dannhoff, T. E. Evans, T. M. Johnson, J. H. Kunimune, Y. Lawrence, J. A. Pearcy, B. L. Reichelt, C. W. Wink, L. Russell, M. Gatu Johnson, R. D. Petrasso, J. A. Frenje; Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates. Rev. Sci. Instrum. 1 September 2024; 95 (9): 093531.
Version: Final published version

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.