MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A comparison of point-tracking algorithms in ultrasound videos from the upper limb

Author(s)
Magana-Salgado, Uriel; Namburi, Praneeth; Feigin-Almon, Micha; Pallares-Lopez, Roger; Anthony, Brian
Thumbnail
Download12938_2023_Article_1105.pdf (3.058Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution http://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Abstract Tracking points in ultrasound (US) videos can be especially useful to characterize tissues in motion. Tracking algorithms that analyze successive video frames, such as variations of Optical Flow and Lucas–Kanade (LK), exploit frame-to-frame temporal information to track regions of interest. In contrast, convolutional neural-network (CNN) models process each video frame independently of neighboring frames. In this paper, we show that frame-to-frame trackers accumulate error over time. We propose three interpolation-like methods to combat error accumulation and show that all three methods reduce tracking errors in frame-to-frame trackers. On the neural-network end, we show that a CNN-based tracker, DeepLabCut (DLC), outperforms all four frame-to-frame trackers when tracking tissues in motion. DLC is more accurate than the frame-to-frame trackers and less sensitive to variations in types of tissue movement. The only caveat found with DLC comes from its non-temporal tracking strategy, leading to jitter between consecutive frames. Overall, when tracking points in videos of moving tissue, we recommend using DLC when prioritizing accuracy and robustness across movements in videos, and using LK with the proposed error-correction methods for small movements when tracking jitter is unacceptable.
Date issued
2023-05-24
URI
https://hdl.handle.net/1721.1/150827
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering; Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Publisher
BioMed Central
Citation
BioMedical Engineering OnLine. 2023 May 24;22(1):52
Version: Final published version

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.