| dc.contributor.author | Minami, Yoshiyasu | |
| dc.contributor.author | Wang, Zhao | |
| dc.contributor.author | Aguirre, Aaron D | |
| dc.contributor.author | Lee, Stephen | |
| dc.contributor.author | Uemura, Shiro | |
| dc.contributor.author | Soeda, Tsunenari | |
| dc.contributor.author | Vergallo, Rocco | |
| dc.contributor.author | Raffel, Owen C | |
| dc.contributor.author | Barlis, Peter | |
| dc.contributor.author | Itoh, Tomonori | |
| dc.contributor.author | Lee, Hang | |
| dc.contributor.author | Fujimoto, James | |
| dc.contributor.author | Jang, Ik-Kyung | |
| dc.date.accessioned | 2021-10-27T20:04:18Z | |
| dc.date.available | 2021-10-27T20:04:18Z | |
| dc.date.issued | 2016 | |
| dc.identifier.uri | https://hdl.handle.net/1721.1/134282 | |
| dc.description.abstract | Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. Objective Methods for intravascular assessment of the side-branch (SB) orifice after stenting are not readily available. The aim of this study was to assess the utility of an en-face projection processing for optical coherence tomography (OCT) images for SB evaluation. Methods Measurements of the SB orifice obtained using en-face OCT images were validated using a phantom model. Linear regression modeling was applied to estimated area measurements made on the en-face images. The SB orifice was then analyzed in 88 patients with bifurcation lesions treated with either Xience V (everolimus-eluting stent) or Resolute Integrity [zotarolimus-eluting stent (ZES)]. The SB orifice area (A) and the area obstructed by struts (B) were calculated, and the %open area was evaluated as (A-B)/A∗100. Results Linear regression modeling demonstrated that the observed departures of the intercept and slope were not significantly different from 0 (-0.12± 0.22, P=0.59) and 1 (1.01± 0.06, R2=0.88, P=0.87), respectively. In cases without SB dilatation, the %open area was significantly larger in the everolimus-eluting stent group (n=25) than in the ZES group [n=32; 89.2% (83.7-91.3) vs. 84.3% (78.9-87.8), P=0.04]. A significant difference in %open area between cases with and those without SB dilatation was demonstrated in the ZES group [91.4% (86.1-94.0) vs. 84.3% (78.9-87.8), P=0.04]. Conclusion The accuracy of SB orifice measurement on an en-face OCT image was validated using a phantom model. This novel approach enables quantitative evaluation of the differences in SB orifice area free from struts among different stent types and different treatment strategies in vivo. | |
| dc.language.iso | en | |
| dc.publisher | Ovid Technologies (Wolters Kluwer Health) | |
| dc.relation.isversionof | 10.1097/MCA.0000000000000319 | |
| dc.rights | Creative Commons Attribution-Noncommercial-Share Alike | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | PMC | |
| dc.title | Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents | |
| dc.type | Article | |
| dc.identifier.citation | Minami, Y., et al. "Quantitative Analysis of the Side-Branch Orifice after Bifurcation Stenting Using En-Face Processing of Oct Images: A Comparison between Xience V and Resolute Integrity Stents." Coron Artery Dis 27 1 (2016): 19-28. | |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science | |
| dc.contributor.department | Massachusetts Institute of Technology. Research Laboratory of Electronics | |
| dc.relation.journal | Coronary Artery Disease | |
| dc.eprint.version | Author's final manuscript | |
| dc.type.uri | http://purl.org/eprint/type/JournalArticle | |
| eprint.status | http://purl.org/eprint/status/PeerReviewed | |
| dc.date.updated | 2019-06-21T18:12:43Z | |
| dspace.orderedauthors | Minami, Y; Wang, Z; Aguirre, AD; Lee, S; Uemura, S; Soeda, T; Vergallo, R; Raffel, OC; Barlis, P; Itoh, T; Lee, H; Fujimoto, J; Jang, I-K | |
| dspace.date.submission | 2019-06-21T18:12:44Z | |
| mit.journal.volume | 27 | |
| mit.journal.issue | 1 | |
| mit.metadata.status | Authority Work and Publication Information Needed | |