Show simple item record

dc.contributor.advisorRichard C. Larson.en_US
dc.contributor.authorLeow, Woei Ling.en_US
dc.contributor.otherMassachusetts Institute of Technology. Engineering Systems Division.en_US
dc.date.accessioned2013-04-12T19:28:12Z
dc.date.available2013-04-12T19:28:12Z
dc.date.copyright2012en_US
dc.date.issued2012en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/78480
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Engineering Systems Division, 2012.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 138-144).en_US
dc.description.abstractOccupancy-moderated zonal space-conditioning (OZS) refers to the partitioning of a residence into different zones and independently operating the space-conditioning equipment of each zone based on its occupancy. OZS remains largely unexplored in spite of its potential to reduce the cost of space-conditioning. Despite the excitement surrounding cloud-connected devices like mobile phones and tablet computers, the benefit of using them to aid energy management agents (EMAs) in reducing space-conditioning cost under demand-driven pricing of electricity is not well understood. We develop a novel framework and the algorithms to enable an EMA to implement OZS for multiple inhabitants under a demand-driven pricing scheme for electricity. We further investigate the effects that influencing factors can have on the effectiveness of OZS under different scenarios using Monte Carlo simulations. The simulation results demonstrate that OZS is realizable on a simple home computer and can achieve significant space-conditioning cost reductions in practice. In our studies, both the financial operating cost of space-conditioning and the cost associated with discomfort are included in a single aggregate cost function. We then expand the simulations to study the cost reduction that is achievable when using cloud-connected devices to provide remote schedule updates to an EMA. This part of the study reveals that reduction in space-conditioning cost is appreciable if a working resident remotely updates an EMA at mid-day of his return time in the evening. In addition, we establish a directly proportional relationship between the level of space-conditioning cost reduction achievable and the variance of return time. Based on the research findings, we further offer recommendations and ideas for future research on the use of OZS and remote schedule updates to different stakeholders like policy-makers and homeowners.en_US
dc.description.statementofresponsibilityby Woei Ling Leow.en_US
dc.format.extent147 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectEngineering Systems Division.en_US
dc.titleZoning and occupancy-moderation for residential space-conditioning under demand-driven electricity pricingen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Engineering Systems Division
dc.identifier.oclc834574218en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record