Show simple item record

dc.contributor.authorPark, Dongkeunen_US
dc.contributor.authorChoi, Yoonhyucken_US
dc.contributor.authorLi, Yien_US
dc.contributor.authorLee, Wooseungen_US
dc.contributor.authorTanaka, Hiromien_US
dc.contributor.authorBascuñán, Juanen_US
dc.contributor.authorAckerman, Jerome L.en_US
dc.contributor.authorTanaka, Hidekien_US
dc.contributor.authorIwasa, Yukikazuen_US
dc.date.accessioned2025-03-21T20:12:30Z
dc.date.available2025-03-21T20:12:30Z
dc.date.issued2019-04
dc.identifier19ja040
dc.identifier.urihttps://hdl.handle.net/1721.1/158577
dc.descriptionSubmitted for publication in IEEE Transactions on Applied Superconductivity
dc.description.abstractWe have finalized the design of a full-scale tabletop 1.5-T/90-mm MgB2 finger MRI magnet system for osteoporosis screening based on our preliminary test results of small coils and superconducting joints.The magnet will operate in persistent mode at 10 K with an additional 5 K temperature margin. The magnet design which includes six main coils and an iron shield satisfies the required specification of a field intensity of 1.5T, homogeneity of≤5 ppm over a 20-mm diameter of spherical volume, and a fringe field of ≤5 gauss at 0.5 m in radius from the magnet center. An active protectionmethod using external heaters will be applied to prevent a local hot spot in the MgB2 windings from being overheated when quench occurs. Active shield transverse and axial gradient coils for this tabletop osteoporosis MRI, having primary and shield coil pairs, are designed to minimize stray fields that can induce eddy currents on nearby metal surface and thus imaging artifacts. This paper covers design and analysis of: 1) the main coils and iron shield; 2) coil former; 3) quench protection; and 4) active shield gradient coils.We also discuss design changes of the cryostat and equipment plan for the overall system. The magnet system will be completed and then, equipped with other MRI hardware components including an in-house-made gradient coil assembly and RF coils for demonstration of 1.5-T finger MRI in 2020.
dc.publisherIEEEen_US
dc.relation.isversionofdoi.org/10.1109/TASC.2020.2981295
dc.sourcePlasma Science and Fusion Centeren_US
dc.titleDesign of a Magnet and Gradient Coils for a Tabletop Liquid-Helium-Free, Persistent-Mode 1.5-T MgB2 Osteoporosis MRIen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Plasma Science and Fusion Center
dc.relation.journalIEEE Transactions on Applied Superconductivity


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record