Now showing items 37-39 of 80

    • Heat transfer and pressure drop data for high heat flux densities to water at high subcritical pressures 

      Rohsenow, Warren M.; Clark, John A. (Cambridge, Mass. : M.I.T. Division of Industrial Cooperation, 1951, 1951)
      Local surface ooeffioients of heat t-ansfer, overall pressure drop data and mean friction factor are presented for heat flamms up to 3.52106 BtuAr ft2 for water flowing in a nickel tabe isder the following conditions: mass ...
    • Heat transfer during film condensation of a liquid metal vapor 

      Sukhatme, S. P.; Rohsenow, Warren M. (Cambridge, Mass. : M.I.T. Dept. of Mechanical Engineering, [1964], 1964)
      The object of this investigation is to resolve the discrepancy between theory and experiment for the case of heat transfer durirnfilm condensation of liquid metal vapors. Experiments by previous investigators have yielded ...
    • The effect of nonuniform axial heat flux distribution on the critical heat flux 

      Todreas, Neil E.; Rohsenow, Warren M. (Cambridge, Mass. : M.I.T. Dept. of Mechanical Engineering, [1965], 1965)
      A systematic experimental and analytic investigation of the effect of nonuniform axial heat flux distribution on critical heat rilux was performed with water in the quality condition. Utilizing a model which ascribes the ...