Show simple item record

dc.contributor.authorHorn, Berthold K.P.
dc.contributor.authorInoue, Hirochika
dc.date.accessioned2008-04-10T13:45:11Z
dc.date.available2008-04-10T13:45:11Z
dc.date.issued1974-05
dc.identifier.urihttp://hdl.handle.net/1721.1/41104
dc.descriptionThis report describes research done at the Artificial Intelligence Laboratory of the Massachusetts Institute of Technology. Support for the laboratory's artificial intelligence research is provided in part by the Advanced Research Projects Agency of the Department of Defense under Office of Naval Research contract N00014-70-A-0362-0005.en
dc.description.abstractThis paper describes the basic geometry of the electric manipulator designed for the Artificial Intelligence Laboratory by Victor Scheinman while on leave from Stanford University. The procedure for finding a set of joint angles that will place the terminal device in a desired position and orientation is developed in detail. This is on of the basic primitives that an arm controller should have. The orientation is specified in terms of Euler-angles. Typically eight sets of joint angles will produce the same terminal device position and orientation.en
dc.description.sponsorshipMIT Artificial Intelligence Laboratoryen
dc.language.isoen_USen
dc.publisherMIT Artificial Intelligence Laboratoryen
dc.relation.ispartofseriesMIT Artificial Intelligence Laboratory Working Papers, WP-69en
dc.titleKinematics of the MIT-AI-VICARM Manipulatoren
dc.typeWorking Paperen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record